ABC CHARGERS 24V
The microprocessor-controlled LEAB ABC battery chargers guarantee effective and gentle battery charging for a safe start-up and a long battery life despite high load.
They are ideal for use in:
- Fire-fighting vehicles
- Mobile command centres
- Rescue vehicles
- First responder vehicles
- Fire engines
- Municipal and service vehicles
- Other special-purpose vehicles
- Trucks
- Buses
The charging characteristics of the ABC chargers can be set for wet cell, gel, AGM and drive batteries. The devices fulfil many standards including EN 60335-2-29, EN 55022 B, EN 61000-3-2, EN 61000-4-2, EN 61000-4-4, EN 61000-4-11, ENV 50140, ENV 50204, DIN 14679. Marks of conformity CE, E acc. to 95/54/EC (EMC guidelines for vehicles) are also available.
ABC Chargers:
- numerous basic models available
- IU1U2 charging characteristics can be set
- multi-coloured LED lights indicate charging status
- handles major deviations in incoming voltage
- reliable charge
Selecting the Right Charger
Most battery manufacturers recommend a charging capacity for their batteries of 10 to 30% of the battery's nominal capacity (Ah). For this reason, most automatic chargers are specified for a certain range of battery sizes. This means, for example, that a 15 amp charger is suitable for batteries with capacities of 40 - 150Ah.
However, some applications such as hand-held lamps, radios, DC chargers, refrigerators, lights, etc., require operational feed while charging the battery. This means that part of the charging power is diverted and effectively reduced. As a result, this consumption must be taken into account when determining the loading capacity so as to achieve a charge that is fast, sufficient and protects the battery.
Type | Art. no.: | Charge current [A] | Bat. capacity [Ah] | Type / class of protection | Sensor / ext. LED | L x W x H [mm] | Weight [kg] | DC cable [m] / [mm²] |
---|---|---|---|---|---|---|---|---|
ABC 2415 | 0101036015 | 15 | 40 - 150 | IP 21 / I | Option / Option | 220 x 112 x 73 | 1,5 | 2 / 2 x 6 |
ABC 2420 | 0101036020 | 20 | 50 - 200 | IP 21 / I | Option / Option | 220 x 112 x 73 | 2 | 2 / 2 x 6 |
ABC 2420 CBL | 0101036024 | 20 | 50 - 200 | IP 21 / I | Option / Option | 220 x 112 x 73 | 2 | 2 / 2 x 6 |
ABC 2420 IP44 | 0101036220 | 20 | 50 - 200 | IP 44 / I | nein / nein | 350 x 176 x 83 | 2 | 2 / 2 x 6 |
ABC 2420-II | 0101236020 | 20 | 50 - 200 | IP 21 / II | Option / Option | 240 x 135 x 85 | 2 | 2 / 2 x 6 |
ABC 2425 IP44 | 0101036225 | 25 | 60 - 250 | IP 44 / I | nein / nein | 350 x 176 x 83 | 2,2 | 2 / 2 x 6 |
ABC 2430 | 0101036030 | 30 | 75 - 300 | IP 21 / I | Option / Option | 220 x 112 x 73 | 1,5 | 2 / 2 x 6 |
ABC 2430 CBL | 0101036034 | 30 | 75 - 300 | IP 21 / I | Option / Option | 220 x 112 x 73 | 1,5 | 2 / 2 x 6 |
ABC 2430-II | 0101236030 | 30 | 75 - 300 | IP 21 / II | Option / Option | 240 x 135 x 85 | 2 | 2 / 2 x 6 |
ABC 2440 | 0101036040 | 40 | 100 - 400 | IP 21 / I | Option / Option | 265 x 135 x 85 | 2,6 | 2 / 2 x 10 |
ABC 2450 | 0101036050 | 50 | 125 - 500 | IP 21 / I | Option / Option | 265 x 135 x 85 | 2,6 | 2 / 2 x 10 |
ABC 2460 | 0101036060 | 60 | 150 - 600 | IP 21 / I | Option / Option | 265 x 135 x 85 | 2,6 | 2 / 2 x 10 |
ABC 2480 | 0101036080 | 80 | 200 - 800 | IP 21 / I | Option / nein | 420 x 255 x 86 | 9,6 | 2 / 2 x 35 |
ABC 24100 | 0101036100 | 100 | 250 - 1000 | IP 21 / I | Option / nein | 420 x 255 x 86 | 9,6 | 2 / 2 x 35 |
ABC 24125 | 0101036110 | 125 | 310 - 1250 | IP 21 / I | Option / nein | 420 x 255 x 86 | 9,6 | 2 / 2 x 35 |
Details | Specification |
---|---|
Characteristic curve | IU1U2 preassigned, 16 characteristic curves stored in E-Prom |
Input voltage [V] / [Hz] | 230 / 40 - 60 |
min. / max. input voltage [V] | 90/ 260 |
Temperature range [°C] | -25 to +55 |
AC cable [m] | 1.5 with Schuko plug |
Cooling | temperature controlled fan |
Short-circuit proof | yes |
Reverse voltage protection | yes |
Standards | EN 60335-2-29, EN 55022 B, EN 61000-3-2, EN 61000-4-2, EN 61000-4-4, EN 61000-4-11, ENV 50140, ENV 50204, DIN 14679 |
Mark of conformity | CE, E acc. to 95/54/EG (EMC guidelines for vehicles) |
- Also available mounted in 19" rack, 3RU, max. 4 modules per unit, combinations with ABC chargers and power supplies possible.
- CBL = Potential-free switching contact, switches at 230V supply to the charger.